22 Operations Manual UWEX
®
722 C
_________________________________________________________________________
___________________________________________________________________
© 2005, Ebinger Prüf- und Ortungstechnik GmbH.
12. Technical Data
- Power supply.
1 x 9V E-Block (6LR61 or U9VL)
- Service life Approx. 20 h (lithium 40 h) at +20° C
- Temperature range.
-20°C to +55°C
Dimensions.
- Search head
Approx. 200 mm Ø
- Length
Approx. ø 40mm x 600mm
Short version approx. 60 cm
Long version approx. 118 cm
Weight.
Approx. 1,6 – 1,8 kg
- Transit case
Approx. 5 kg
Detection ranges factor*
approx. 3
application range top layer of soil between approx. 0,1 to 1 m
depending on size, material and position
of metal object and local interfere
nce
*detection range factor describes the system sensitivity in air and without interference.
A factor of three means three means that a metal disc of the same size as the search head
(here 200 mm) will be detected at a distance of three times of this dimension (equal 60 cm) .